Commissioning
HTX30 Product Manual
5-50
Error message
Comments
Stbd throttle has gone into backup
The test aborted because the starboard propulsion line has
been placed in backup mode
The backup jogstick of the station control panel (SCP) that is in
control now has control
Ensure that all propulsion lines are in normal mode, then rerun
the test
The following modules can no
longer be seen:
x
Where
x
can be: EIM 1, EIM 2, JACM
1, JIM 1, JIM 2
The test aborted when the control system lost communication
with the specified module
The JETanchor Mouseboat has control of all waterjets and
engines that are available for remote (normal) control
Check that all cables to the missing module are in good
condition and securely connected
Check the missing module for faults
Resolve any issues, then rerun the test