SERVICE & WEB MONITORING TOOL
5545
554555 SERVICE TOOL
MODEL : UTY 5 ASGX
Extensive monitoring and analysis functions for installation and maintenance.
Operation status and error history can be grasped promptly and adequately.
FEATURES
1) Operation status can be checked and analyzed to detect even the small abnormalities.
2) Data collected and stored on site can be checked later, off-line, off-site for more detail
analysis.
3) One VRF network system with maximum number of up to 400 units can be monitored and
controlled.
4) Operation status and various sensor information can be monitored and checked real time in
the form of list, refrigerant circuit diagram, graphs as well.
5) Simple operation control functions are useful during maintenance.
6) The recent error history can be retrieved from units on demand to perform analysis on the
cause of the error, after connecting Service Tool to the VRF network system.
7) Commissioning tool supports test runs, data storage for each unit and saving of data as
CSV files, which may be formatted to create commissioning report.
8) Connectable to any point of transmission line with USB adaptor *1 (field supplied)
*1 : Service Tool (UTY-ASGX) will only support USB type network adaptor and will not support transmission
adaptor of the traditional type(UTR-YTMA)
FUNCTIONS
5) System List
Displays the overall operation status of all or specified units in
the system in a list form.
2) Equipment Detail (Diagram)
Displays the detail information for sensor values, electrical
components etc. for the specified units in schematic. The
information here can be used along with the detail information
in list form, to check the operation status of units and make
detail analysis on the cause, in case an error occurs.
3) Equipment Detail (List)
Displays the detail information for sensor values, electrical
components etc. of units in a specified refrigerant system in list
form. The information here can be used along with the detail
information in diagram form, to check the operation status of
units and make detail analysis on the cause, in case an error
occurs.
Software
- (05 - 78) -
C
O
N
TRO
L
SY
ST
EM
C
O
N
TRO
L
SY
ST
EM
Summary of Contents for AIRSTAGE V-II
Page 10: ...1 GENERAL INFORMATION ...
Page 32: ...2 MODEL SELECTION ...
Page 207: ...3 OUTDOOR UNITS ...
Page 251: ...SOUND LEVEL CHECK POINT Microphone 1 m 1 m 03 44 OUTDOOR UNITS OUTDOOR UNITS ...
Page 265: ...4 INDOOR UNITS ...
Page 315: ...MODEL ARXB45 04 50 INDOOR UNITS INDOOR UNITS ...
Page 316: ...4 5 5 DUCT TYPE MODEL ARXA24 MODELS ARXA30 ARXA36 ARXA45 04 51 INDOOR UNITS INDOOR UNITS ...
Page 318: ...4 5 7 FLOOR CEILING TYPE MODELS AB A12 AB A14 AB A18 AB A24 04 53 INDOOR UNITS INDOOR UNITS ...
Page 319: ...4 5 8 CEILING TYPE MODELS AB A30 AB A36 AB A45 AB A54 04 54 INDOOR UNITS INDOOR UNITS ...
Page 322: ...4 5 11 WALL MOUNTED TYPE MODELS AS A18 AS A24 AS A30 04 57 INDOOR UNITS INDOOR UNITS ...
Page 388: ...5 CONTROL SYSTEM ...
Page 472: ...6 SYSTEM DESIGN ...
Page 694: ...7 OPTIONAL PARTS ...