ELECTRIC CHARACTERISTICS
4434
MCA : Min Circuit Amps = Max Operating Current (Full Load).
MFA : Main Fuse (Circuit breaker) Amps.
Indoor Unit
Power Supply
Indoor Fan Motor
Type
Model
VoltaHe
(V)
Frequency
(Hz)
MCA MFA
Input Power
Full Load Amp
(A)
(A)
(kW)
(A)
Compact Cassette
AUXB07LALH
230~
50
0.20
15
0.025
0.17
AUXB09LALH
0.20
0.025
0.17
AUXB12LALH
0.24
0.029
0.20
AUXB14LALH
0.29
0.035
0.24
AUXB18LALH
0.30
0.036
0.25
AUXB24LALH
0.75
0.084
0.62
Cassette (Slim Type)
AUXD18LALH
230 ~
50
0.32
15
0.039
0.27
AUXD24LALH
0.38
0.046
0.32
Cassette
AUXA30LALH
230 ~
50
0.51
15
0.059
0.42
AUXA36LALH
0.64
0.080
0.53
AUXA45LALH
0.83
0.099
0.69
AUXA54LALH
0.94
0.119
0.78
Compact Duct
ARXB07LALH
230 ~
50
0.29
15
0.046
0.24
ARXB09LALH
0.30
0.055
0.25
ARXB12LALH
0.36
0.063
0.30
ARXB14LALH
0.48
0.090
0.40
ARXB18LALH
0.51
0.096
0.42
Low Static
Pressure Duct
ARXB24LATH
230 ~
50
0.78
15
0.145
0.65
ARXB30LATH
1.02
0.198
0.85
ARXB36LATH
1.48
0.253
1.23
ARXB45LATH
1.88
0.338
1.56
Duct
ARXA24LATH
230 ~
50
1.07
15
0.190
0.89
ARXA30LATH
1.08
0.188
0.90
ARXA36LATH
1.79
0.312
1.49
ARXA45LATH
1.79
0.312
1.49
High Static
Pressure Duct
ARXC36LATH
230 ~
50
2.11
15
0.405
1.76
ARXC45LATH
2.22
0.427
1.85
ARXC60LATH
2.22
0.427
1.85
ARXC72LATH
5.82
1.110
4.85
ARXC90LATH
6.55
1.250
5.47
Floor / Ceiling
AB
A12LATH
230 ~
50
0.30
15
0.057
0.25
AB
A14LATH
0.30
0.057
0.25
AB
A18LATH
0.45
0.088
0.38
AB
A24LATH
0.45
0.088
0.38
Ceiling
AB
A30LATH
230 ~
50
1.36
15
0.124
1.14
AB
A36LATH
1.39
0.144
1.16
AB
A45LATH
1.40
0.160
1.17
AB
A54LATH
1.40
0.180
1.17
Compact
Wall Mounted
(EEV external Model)
AS
E07LACH
230 ~
50
0.18
15
0.015
0.15
AS
E09LACH
0.18
0.016
0.15
AS
E12LACH
0.23
0.020
0.19
AS
E14LACH
0.34
0.028
0.28
Compact
Wall Mounted
(EEV internal Model)
AS
A07LACH
230 ~
50
0.20
15
0.016
0.17
AS
A09LACH
0.21
0.016
0.18
AS
A12LACH
0.24
0.019
0.20
AS
A14LACH
0.34
0.030
0.28
Wall Mounted
AS
A18LATH
230 ~
50
0.41
15
0.063
0.34
AS
A24LATH
0.42
0.074
0.35
AS
A30LATH
0.41
0.073
0.34
- (04 - 22) -
IND
OO
R
UN
IT
S
IND
OO
R
UN
IT
S
Summary of Contents for AIRSTAGE V-II
Page 10: ...1 GENERAL INFORMATION ...
Page 32: ...2 MODEL SELECTION ...
Page 207: ...3 OUTDOOR UNITS ...
Page 251: ...SOUND LEVEL CHECK POINT Microphone 1 m 1 m 03 44 OUTDOOR UNITS OUTDOOR UNITS ...
Page 265: ...4 INDOOR UNITS ...
Page 315: ...MODEL ARXB45 04 50 INDOOR UNITS INDOOR UNITS ...
Page 316: ...4 5 5 DUCT TYPE MODEL ARXA24 MODELS ARXA30 ARXA36 ARXA45 04 51 INDOOR UNITS INDOOR UNITS ...
Page 318: ...4 5 7 FLOOR CEILING TYPE MODELS AB A12 AB A14 AB A18 AB A24 04 53 INDOOR UNITS INDOOR UNITS ...
Page 319: ...4 5 8 CEILING TYPE MODELS AB A30 AB A36 AB A45 AB A54 04 54 INDOOR UNITS INDOOR UNITS ...
Page 322: ...4 5 11 WALL MOUNTED TYPE MODELS AS A18 AS A24 AS A30 04 57 INDOOR UNITS INDOOR UNITS ...
Page 388: ...5 CONTROL SYSTEM ...
Page 472: ...6 SYSTEM DESIGN ...
Page 694: ...7 OPTIONAL PARTS ...