PACKING LIST
Remote central control
z
System Controller can be managed remotely over the internet using client program.
●
Server programs run in VRF sites, and client programs run in remote sites with users.
●
Item
Q'ty
Application
CD
1
Includes the software for System Controller. Both server and client
software are included.
Wibu Key
(Software
protection key)
1
Software protection key to be inserted in a USB slot running System
Controller. System Controller may only run on a PC with Wibu Key.
Remote client software is not required Wibu Key.
Personal computer must be field supplied.
U10 USB Network Interface must be field supplied. Contact Echelon
®
Corporation or its local sales representative for detail.
Product Name : U10 USB Network Interface – TP/FT-10 Channel
Model Number: 75010R
OPERATING CONDITIONS
The following chart shows the detail requirement for an AT compatible personal computer to run
System Controller.
Requirement for PC running System Controller (UTY-APGX)
CPU
Intel
®
Pentium
®
/ Celeron
®
2GHz or higher (1GHz for client only PC)
Hard Drive
40GB or more of free space. (5GB for client only PC)
Memory
2GB or more (1GB or more for client only PC)
Display
Display supporting 1024 x 768 dots or more.
15 inch or higher size is preferable.
Interface
USB port is required for each of the followings for on site PC;
Wibu Key (Software protection key)
•
Echelon
•
®
U10 USB Network Interface (Required for each VRF
Network)
Ethernet port is required for remote connection.
Operating System
Windows
®
Vista Home Premium, Business Edition
Windows
®
XP Professional with Service Pack 2 or later
Other Software Required Adobe
®
Acrobat
®
reader 4.0 or later.
Accelerator
Requires the graphics accelerator be compatible with Microsoft
®
DirectX
®
9.0 or later.
1 client can control or monitor up to 10
●
System Controllers (10 VRF sites).
1 System Controller can be monitored from
●
up to 5 clients.
Client
Internet
or
Telephone Line
or
LAN
Server
Server
Server
Server
Server
Internet
or
Telephone Line
or
LAN
Server
Client
Client
Client
Client
Client
System Controller
System Controller System Controller System Controller
System Controller
System Controller
System Controller
System Controller
System Controller
System Controller
System Controller
System Controller
Sites
with VRF
systems
Site with
VRF
system
Remote central control (
Controlled sites of up to 10)
Remote central control (
Monitored from up to 5 Clients)
- (05 - 14) -
C
O
N
TRO
L
SY
ST
EM
C
O
N
TRO
L
SY
ST
EM
Summary of Contents for AIRSTAGE V-II
Page 10: ...1 GENERAL INFORMATION ...
Page 32: ...2 MODEL SELECTION ...
Page 207: ...3 OUTDOOR UNITS ...
Page 251: ...SOUND LEVEL CHECK POINT Microphone 1 m 1 m 03 44 OUTDOOR UNITS OUTDOOR UNITS ...
Page 265: ...4 INDOOR UNITS ...
Page 315: ...MODEL ARXB45 04 50 INDOOR UNITS INDOOR UNITS ...
Page 316: ...4 5 5 DUCT TYPE MODEL ARXA24 MODELS ARXA30 ARXA36 ARXA45 04 51 INDOOR UNITS INDOOR UNITS ...
Page 318: ...4 5 7 FLOOR CEILING TYPE MODELS AB A12 AB A14 AB A18 AB A24 04 53 INDOOR UNITS INDOOR UNITS ...
Page 319: ...4 5 8 CEILING TYPE MODELS AB A30 AB A36 AB A45 AB A54 04 54 INDOOR UNITS INDOOR UNITS ...
Page 322: ...4 5 11 WALL MOUNTED TYPE MODELS AS A18 AS A24 AS A30 04 57 INDOOR UNITS INDOOR UNITS ...
Page 388: ...5 CONTROL SYSTEM ...
Page 472: ...6 SYSTEM DESIGN ...
Page 694: ...7 OPTIONAL PARTS ...