444424 CASSETTE TYPE
MODELS : AUXD48, AUXD24, AUXA30, AUXA36, AUXA45, AUXA54
FEATURES
High efficiency turbo fan with 3-dimensional blade
z
High lift drain pump
z
Adjustment of hanger position is
z
possible after installation
One way aperture installation
z
Optional parts
z
IR Receiver Unit : UTY-LRH
●
B1
Air Outlet Shutter Plate : UTY-YDZC
●
Panel Spacer : UTG-BGYA-W
●
Wide Panel : UTG-AGYA-W
●
Insulation Kit
●
for High Humidity
: UTZ-KXGA
(for AUXA30-54)
: UTZ-KXGB
(for AUXD18,24)
450mm
500mm
Previous turbo fan
High efficiency airflow distribution has
been achieved by the introduction of a 3
dimensional blade which increases the
air passing over the heat exchanger.
Air passing through the heat
exchanger was uneven and the air
would only flow close to the ceiling.
Separation
phenomenon of
airflow causes noise
No airflow
separation
3-dimensional blade
Spin direction
Airflow direction
Turbulent flow noise
Conventional
blade
Wind
velocity
Fast
Slow
Heat exchanger
< Motor side >
Heat exchanger
< Motor side >
Uneven airflow
New turbo fan
Quiet
Previous louvre
Bottom view
Bottom view
Round louvre
Front part
Front part
Louvre
Rear
part
Rear
part
Ceiling
Ceiling
New louvre
As the airflow follows the ceiling it does not
allow the airflow to be widely distributed.
The louvre design distributes air leaving a
space between the chassis and the ceiling
allowing far and wide air flow distribution.
Temperature irregularity happens
Much less temperature
irregularity happens by spreading
airflow widely
850mm
Ceiling panel
Detachable
grille corner
Adjustment
can be done just taking
off the corner part
Several
way
apertures
Parallel
apertures
Previous model
New model
- (04 - 02) -
IND
OO
R
UN
IT
S
IND
OO
R
UN
IT
S
Summary of Contents for AIRSTAGE V-II
Page 10: ...1 GENERAL INFORMATION ...
Page 32: ...2 MODEL SELECTION ...
Page 207: ...3 OUTDOOR UNITS ...
Page 251: ...SOUND LEVEL CHECK POINT Microphone 1 m 1 m 03 44 OUTDOOR UNITS OUTDOOR UNITS ...
Page 265: ...4 INDOOR UNITS ...
Page 315: ...MODEL ARXB45 04 50 INDOOR UNITS INDOOR UNITS ...
Page 316: ...4 5 5 DUCT TYPE MODEL ARXA24 MODELS ARXA30 ARXA36 ARXA45 04 51 INDOOR UNITS INDOOR UNITS ...
Page 318: ...4 5 7 FLOOR CEILING TYPE MODELS AB A12 AB A14 AB A18 AB A24 04 53 INDOOR UNITS INDOOR UNITS ...
Page 319: ...4 5 8 CEILING TYPE MODELS AB A30 AB A36 AB A45 AB A54 04 54 INDOOR UNITS INDOOR UNITS ...
Page 322: ...4 5 11 WALL MOUNTED TYPE MODELS AS A18 AS A24 AS A30 04 57 INDOOR UNITS INDOOR UNITS ...
Page 388: ...5 CONTROL SYSTEM ...
Page 472: ...6 SYSTEM DESIGN ...
Page 694: ...7 OPTIONAL PARTS ...