A.2.4 Disassembly of the Boil Over Sensor
●
Disconnect the dispenser from the mains
supply and close the water supply valve.
●
Remove the housing cover (see pg. 5.G-2).
●
Remove the air chute (see pg. 5.G-5).
●
Remove the boil over sensor (1) from the
overflow cover. (Fig. 1)
●
Unplug the flat plugs.
●
Connect the flat plugs (2) to the new
sensor and install the new sensor. (Fig. 1)
2
1
Fig. 1