January 2001
5A - 14
Functions - Water System
Service Manual Cafitesse 500
A.2.6 Disassembly of the Optical Sensor
Fig. 1
Preparation:
●
Disconnect the dispenser from the mains
supply and close the water supply valve.
●
Remove the housing cover (see pg. 5.G-2).
●
Remove the air chute (see pg. 5.G-5).
Disassembly:
●
Take the float support out of the optical
sensor (pull it up and turn it sideways).
●
Unplug the plug from the optical sensor.
(Fig. 1)
●
Remove the defective optical sensor.
●
Insert the new optical sensor into the plate
by means of the snap hooks. (Fig. 1)
●
Connect the plug to the optical sensor.
Make sure the polarity is correct!
●
Insert the float support into the optical
sensor.
●
Assemble the dispenser.