January 2001
5F - 2
Functions - Cooling System
Service Manual Cafitesse
500
4
7
6
3
5
F.2 Disassemblies
F.2.1 Disassembly of the Fan
●
Disconnect the dispenser from the mains
supply and close the water supply valve.
●
Remove the front part (see pg. 5.G-3).
●
Two fans (1) are attached to the special air
chute (3) by means of two screws
respectively (2). (Fig. 1)
A fan plate (4) is installed. (Between fan
and cooling compartment insulation.)
(Fig. 2)
●
When replacing the fans
-
Remove the fan plate (4). (2 screws)
(Fig. 2)
-
Disconnect the socket housing (5) from
the cable harness. (Fig. 2)
-
Remove the screwed rivet (2 pcs) (6)
from the air chute (3). (Fig. 2)
-
Remove the screws (2). (Fig. 1)
CAUTION:
When mounting, ensure that
-
the cooling compartment
insulation will not be
damaged.
-
the upper edge of the air
chute (3) and the heat sink
(7) are aligned. (Fig. 2)
-
the mounting position of
the fans is correct. (In
mounting position, the
arrow (8) must face to the
top) (Fig. 1)
-
the plugs are connected
correctly to the housings
and the cable harness
(Fig. 2)
F.1 Adjustments
Not available
3
2
1
8
Fig. 1
Fig. 2