Functions - Water System
Service Manual Cafitesse 500
A.3.10
Function: Safety System
Safety system (see fig. 1)
●
Heating can be interrupted by:
1. the relay:
The electronic control interrupts the
heating by means of the relay in those
cases where the interruption shall only
be temporarily.
2. an interruption by the safety circuit
this interruption can be triggered by:
-
the watchdog-relay
-
the boil over sensor
-
the dry running protection
These elements are connected in series.