January 2001
5A - 6
Functions - Water System
Service Manual Cafitesse 500
●
Disconnect the ground connection
(5). (Fig. 8)
●
Remove the suspension plates for the boiler
(6) underneath the dispenser cover on all
dispenser sides. (Fig. 9)
●
Remove the plates (7) on all dispenser
sides. (Fig. 9)
●
Remove the boiler (8) to the front. (Fig. 9)
WARNING:
During all remounting work,
make sure that the overflow
hose (9) is correctly mounted
in the base-stay (10). (Fig. 10)
To replace the water drain valves see
page 5A-18
When replacing the boiler insulation,
the boiler insulation itself, the drip
water collector and the Elastosil
adhesive must be ordered individually.
The drip water collector must then be
adhered to the insulation according to
Fig. 11.
The Elastosil adhesive (part no. K-0253)
must be applied on the entire length of
the back side of the drip water
collector (part no. 35207100).
CAUTION:
Make sure, that the indicated
measurements are kept.