January 2001
3 - 10
Trouble Shooting, Error Codes and Fault Diagnosis
Service Manual Cafitesse 500
ERR19
Left mixer motor current
I
mixer
is higher than 2.3 A
after 200 msec.
The LEDs for "EMPTY"
and "ON/OFF" are
flashing.
The dispenser remains on
The delivery of all products
for which the left mixer motor
is used is blocked.
All products for which the
left mixer motor is not used
can be delivered.
Cooling remains on.
During the 'FLUSH'
procedure the defective
mixer remains off.
ERR20
Right mixer motor current
I
mixer
is lower than 0.1 A
for 100 msec
The LEDs for "EMPTY"
and "ON/OFF" are
flashing.
The dispenser remains on
The delivery of all products
for which the right mixer
motor is used is blocked.
All products for which the
right mixer motor is not used
can be delivered.
Cooling remains on.
During the 'FLUSH'
procedure the defective
mixer remains off.
Display
Error
Cause
Remedy
1. Mixer motor moves
sluggishly.
2. Mixer dirty.
3. Plug defective (P06).
4. Motor defective
1. Motor defective
2. Plug defective (P06)
3. Wires P06 to the motor
defective
1. Flush the dispenser on the
left side.
2. Clean the mixer.
3. Replace the plug.
(6-poles connector and
BU23)
4. Check or replace motor if
required (see pg. 5.C-8).
1. Check or replace motor. (see
pg. 5.C-8)
2. Replace the plug. (6-poles
connector and BU23)
3. Check the wires.
(6-poles connector from
whipper motor)