January 2001
2 - 23
Installation / Putting into Operation
Service Manual Cafitesse 500
Electric connection:
Only by power cable and plug. Never hardwire.
The dispenser is radio-shielded acc. to EN 55014/VDE 0875, T14
The dispenser is marked with the CE label. (Directive about
electrical equipment of low voltage, directive about electromagnetic
compatibility)
WARNING:
The connection must be grounded!
We recommend to install a ground fault
current safety switch.
The dispenser is equipped with 2 relays.
Power supply cable: 3x10AWG / 30 A
Length of power supply cable:
approx. 5.9 ft
Boiler:
Open system, capacity 2.64 US gal
electronic control of the water temperature,
dry running protection (electronic monitoring by means of a float
and a temperature limiter for the heating element),
electronic low temperature indicator, electronic boil over sensor
Beverage delivery capacity:
Maximum drinks per hour is dependent on available power and incoming
water temperature
Cooling system:
Thermoelectric cooling: Peltier element, axial blower,
electronically controlled ON/OFF
Power consumption: up to max. 75 W (exclusive fan)