K.2.6 Disassembly of the Operating Panel and the Operating Panel Board
CAUTION:
In order to prevent damaging of
the pc boards and their
components due to electrostatic
charge, first touch a metal table
or a metal cupboard before
touching the pc boards.
●
Disconnect the dispenser from the mains
supply and close the water supply valve.
●
Remove the plexiglass panel (see pg. 5.G-3).
●
Remove the brew basket (1), the combi-
trough and the trough box. (Fig. 1)
●
Loosen the 4 screws (2) at the bottom of
the operating panel. (Fig. 2)
●
Pull the operating panel (3) vertically
downwards. (Fig. 2)
●
Open the box of the interconnector board(4)
and remove the corresponnding plug (5)
from the interconnector board (6). (Fig. 3)
When remounting, make sure that the
interconnector board of the control
board box are positioned correctly.
●
Mounting is done in reverse order.