January 2001
5K - 16
Functions - Power Supply and Control
Service Manual Cafitesse 500
BR
EW
IN
G
MCB
●
The operating panel board (1) is connected to
the service panel board (4) via two cable
harnesses (2, 3) which are plugged to the
interconnector board (5). (Fig. 1)
●
The interconnector board (5) is connected
to the control board by means of an additio-
nal cable harness (6). (Fig. 1)
This cable harness ensures the data
interchange during programming and
product delivery.
●
The following components are situated on
the operating panel board:
-
triggering button left (7)
-
triggering button hot water (8)
-
triggering button right (9)
When actuating a triggering button, a
beverage delivery signal is transferred to
the control unit.
-
STOP button (10)
each beverage
delivery is stopped
-
LEDs (11) for
BREWING-display
(14)
The BREWING-
display is a visual
indication during the
delivery of a
beverage
-
LEDs for empty
indication (12)
-
LED for low
temperature
indication (13)
K.3.4 Function: Operating Panel Board - Service Panel
Fig. 1
15
16
17
18
20
3
4
21
22
23
24
19
7
1
13
10
14
●
The following components are situated on
the service panel:
Display (15)
-
indicates the dispenser status, error
codes and the counter
MODE-button (16), – -button (
17),
+ -button (18)
-
serve for programming via the service panel
ON/OFF-button(19)
-
for switching the dispenser on/off
Key switch (20)
-
serves for reading out the counters and
for programming via the service panel
Connection for the service device (21)
-
for programming the dispenser
Rinse button (22), right (23), café cool (24)
-
serve for rinsing the outlet trough
12
8
9
12
5
6
2
11