January 2001
5A - 8
Functions - Water System
Service Manual Cafitesse 500
●
Remove the housing cover (1). (Fig. 2)
●
Withdraw the inserts (2) on the left and on
the right. (Fig. 2)
●
Remove the air duct.
●
Remove the boiler cover (3) towards the
top. (Fig. 3)
●
Place your hands under the edge of the
boiler cover and pull the cover off towards
the top (reach through the hole (4) in the
carber cover). (Fig. 3)
●
Disconnect the cable connection at the dry
running protection.
●
The heating cable harness (5) must be
disconnected at the 6-pole plug connection
(6). (Fig. 3)
●
Remove the boiler cover from the boiler.
●
When assembling the dispenser make sure:
-
that the air chute is mounted correctly,
-
that the cover sealing (7) is mounted
correctly. The ends must meet in the
central front part. (Fig. 3)
ka
ffe
e
ka
ffe
e
ka
ffe
e
te
e
te
e
te
e
3
Fig. 3
Fig. 2
2
1
2
4
5
6
7