January 2001
5A - 10
Functions - Water System
Service Manual Cafitesse 500
●
Disconnect the dispenser from the mains
supply and close the water supply valve.
●
Loosen the screw at the splash panel and
open the splash panel by pressing it
downwards.
●
Drain the water from the boiler.
WARNING:
The drained water is hot. There
is the danger of being scalded.
Keep your hands and other
parts of your body away from
the hot water.
Water can be drained
-
from the front by opening the splash
panel or
-
from the back by removing the filter
grid.
●
Remove the air chute (see pg. 5.G-5)
CAUTION:
There is a risk of being
scalded by hot water.
●
Remove the boiler cover (see pg. 5.A-7).
●
Pull off the plug from the dry running
protection (8). (Fig. 3)
●
Remove the overflow cover (9) and the flap
underneath it. (Fig. 3)
●
Unwind the old dry running protection (8)
and remove it. (Fig. 3)
●
Decalcify the heating element in the area of
the coil with a suitable decalcifying agent.
●
Unwind the capillary tube of the new dry
running protection.
●
Insert the housing of the dry running
protection (8) into boiler cover edge. (Fig. 3)
●
Stick the capillary tube through the overflow
in the boiler cover.
Fig. 2
Fig. 3
9
8
90 mm
6
9x
8x
1x
9x