January 2001
5D - 4
Functions - Product Delivery
Service Manual Cafitesse 500
co
ffe
e
co
ffe
e
co
ffe
e
co
ffe
e
co
ffe
e
co
ffe
e
sto
p
BR
EW
IN
G
ho
t w
ate
r
D.2.2 Disassembly of the Cup Carrier and the Splash Panel
●
Disconnect the dispenser from the mains
supply and close the water supply valve.
●
Remove the brew basket, the combi-
trough and the trough box.
●
Remove the drip tray and the drip grid.
●
Loosen the screw (1) from the splash panel
(2) and open the splash panel by pressing
it downwards. (Fig. 1)
●
Remove the control system completely with
housing. (see page 5K-4)
●
Unplug the ground connection (4). (Under
all circumstances make sure it is plugged
back in when re-installing.) (Fig. 2)
●
Withdraw the hinge rod (3) towards the top
and remove the splash panel (2). (Fig. 2)
Warning:
When fitting the splash panel,
the following must be
observed in any case:
•
Reconnect the ground
connector (4) to the splash
panel. (Fig. 2)
•
Fasten the screw (1) after
having closed the splash
panel (guidelines according
to VDE - German engineer
association). (Fig. 1)
Fig. 1
2
1
2
Fig. 2
3
4
2