January 2001
4 - 14
Programming
Service Manual Cafitesse 500
FLOW SETTINGS
Test flow is also possible when the
combi-trough has been removed. The
splash panel must be installed.
CAUTION:
The delivered water can be
hot. There is a risk of being
scalded.
●
Main menu: Select Flow settings
Input
Test left flow ?
Adj 140cc Push 0
●
Carry out the test:
●
Place a sufficiently large container (approx.
200cc) under the left outlet.
●
Press
0
●
Measure whether 140cc have been
delivered. If necessary check the product
valve and nozzle. The setting screw on the
product valve must be 3.5 to 3.75 rotations
open.
↓
Test right flow ?
Adj 140cc Push 0
●
Carry out the test:
●
Place a sufficiently large container (approx.
200 cc) under the right outlet.
●
Press
0
●
Measure whether 140 cc have been deli-
vered. If necessary check the product valve
and nozzle. The setting screw on the
product valve must be 3.5 to 3.75 rotations
open.
↓
Test water flow ?
Adj 88cc Push 0
●
Carry out the test:
●
Place a sufficiently large container (approx.
150 cc) under the hot water outlet.
●
Press
0
4.1.2.3.2 Programming the individual Main Menus
●
Measure whether 88cc have been
delivered, if necessary readjust the solenoid
valve for hot water on the boiler with a
gauge, then repeat the test
↓
Test cool flow ?
Adj 40cc Push 0
●
Carry out the test, if necessary adjust the
flow at the dosing unit.