January 2001
5A - 36
Functions - Water System
Service Manual Cafitesse 500
●
Remove the valve outlet (1) from the
support of the nozzler (2) from the product
valve on the right side. (Fig. 4)
●
Remove the bent water outlet (3) from the
valve outlet. (Fig. 4)
●
Mount the tube elbow (4), the nozzle
support (5) and the tube (6) from the kit
according to fig. 5.
●
Mount the bent water inlet (7) to the tube.
(Fig. 5)
●
Put the water inlet hose (8) from the cold
water valve into the nozzle support (5).
(Fig. 5)
●
Assemble the dispenser.
●
Connect the dosing unit (9) to the water
supply system (or to the cooling aggregate)
and connect it to the dispenser (cold water
valve). (Fig. 5)
●
Replace the corresponding push button
cover on the operating panel. (see chap.
G.2)
Programming
see flow chart
●
Enable "Café cool" in the menu 'Machine
settings'.
●
Carry out a test flow in the menu 'Flow
settings' and adjust the cold water flow at
the pressure regulator (10) to 20 ml/sec.
(Fig. 5)
●
For dispenser versions with espresso
delivery disable espresso for the "Café
cool" button.
Fig. 5
4
5
6
7
9
8
Fig. 4
2
1
3
10