January 2001
2 - 25
Installation / Putting into Operation
Service Manual Cafitesse 500
WHAT:
HOW:
Inlet valve
Voltage:
24 V DC
Flow rate:
2.6 gal/min
Temperature:
194 °F
Pressure:
1.45–145 psi
Duty cycle:
100 %
Inlet valve with café cool
Voltage:
24 V DC
Pressure:
0–145 psi
Duty cycle:
100 %
Flow rate:
20 cc/sec.
Boiler
Material:
PPH 2050
Pressure:
atmospheric
Capacity:
2.6 gal
Dry running protection
Triggering temp.:
298.4 °F - 28.8 °F
Thermostat
Temperature:
programmed temperature
-0.5 °F
Programmed temperature is adjustable via
service device
Low temperature indication
Switching-on temp.:
boiler temperature is less
than 141.8 °F
Switching-off temp.:
boiler temperature equals
programmed temperature
-7.2 °F
Disconnecting the heating via relay
Boiler temperature is greater than programmed
temperature
Interrupting the safety circuit by means of
Boiler temperature is greater than programmed
a watchdog relay
temperature +9 °F
ERR 4 switching-off by software
Boiler temperature is greater than 213.8 °F
Optical sensor
see manufacturer indications
Boil over sensor -(Temperature limiter)
Triggering temp.:
190.4 °F ± 5.4 °F
Outlet valve product
Voltage:
24 V DC
Temperature:
208.4 °F
Pressure:
0–0.87 psi
Duty cycle:
100 %
Outlet valve hot water
Voltage:
24 V DC
Temperature:
208.4 °F
Pressure:
0–0.87 psi
Duty cycle:
100 %
2.7.1
Technical Specifications of Components