January 2001
5C - 8
Functions - Dosing System
Service Manual Cafitesse 500
C.2.5 Disassembly of the Mixing Units
●
Disconnect the dispenser from the mains
supply and close the water supply valve.
●
Remove the brew basket, the combitrough
and the trough box.
●
Loosen the screw at the splash panel and
open the splash panel by pressing it
downwards.
●
Disconnect the cable harness connections
at the mixer motors.
●
Remove the impeller (1) by using a screw
driver. (Fig. 1, 2)
Fig. 1
Fig. 2
1
1
2
3
4
5
P6-4 (-)
P6-3 (+)
P6-1 (+)
P6-2 (-)