January 2001
2 - 24
Installation / Putting into Operation
Service Manual Cafitesse 500
Dosing systems:
2 pulsed dosing systems, electronically controlled dosing coil,
pulse driven pump, integrated into the flexi-packs,
electronic "concentrate empty" indicator.
Speed of beverage delivery:
with installed mixer: 1 cup (150 cc) 5 floz
in 10 sec.
Delivery modes:
The delivery mode, the size of a portion and the beverage strength
are adjustable.
Delivery modes: portioned, portion repeated or continuous flow
Further installation requirements: Altitude:
up to 6562 ft
Ambient temperature:
41–90 °F
Distance to wall:
2 in measuring from
the back side of the dispenser
The dispenser is protected from dripping water.
Heating capacities:
The dispenser is equipped with a heating capacity changeover
switch which is used to connect it to all of the commonly used
main voltages / main fuses (see table, page 2-15).
CAUTION: Disconnect the dispenser from the mains before
changing the heating capacity. There is a danger of
destroying the dispenser!
The heating capacity may only be changed by a
trained service technician.
The slip-on rotary switch is a service tool that may
only be used by the Service Technician. It must be
removed after the heating capacity has been
changed.
Affix a corresponding sticker onto the rating plate
after the heating capacity has been adjusted (see
page 2-16).