January 2001
5A - 21
Functions - Water System
Service Manual Cafitesse 500
A.2.11
Disassembly of the Inlet Valve
●
Disconnect the dispenser from the mains
supply and close the water supply valve.
●
Remove the filter grid (1) and the grid plate
(2). (Fig. 1)
●
Drain the water from the boiler. (see pg. 5A-5)
WARNING:
The drained water is hot.
There is the danger of being
scalded. Keep your hands and
other parts of your body away
from the hot water.
●
Dismount the switching power console (see
pg. 5.K-5).
●
Turn the locking device (5) in clockwise
direction. (Fig. 2)
●
Slide the inlet valve (3) and the plate (4)
upwards out of the guide. (Fig. 2)
5
4
3
Fig. 2
B
Fig. 1
A
1
2