January 2001
5K - 15
Functions - Power Supply and Control
Service Manual Cafitesse 500
K.3.3 Function: Control Unit
●
The following components are situated on
the control unit (Fig. 1):
EPROM (2)
-
contains software
EEPROM (3)
-
stores the dispenser adjustments and
the values adjusted during programming
BATTERY (4)
-
3 V
LEDs
-
Operating voltage indication
-
green (5)
-
24 V right
-
yellow (6)
-
24 V left
-
red (7)
-
5 V
Fuse for Peltier element (8)
-
fuse for 24 V left (9)
-
24 V right (10)
●
The control unit (1) completely controls and
monitors the dispenser. (Fig. 1)
This includes
-
temperature regulation for the cooling
and the water system
-
the water level
-
control of the dosing system and the
mixer units
-
the operating panel input and the service
panel input
-
the connection to payment systems and
other peripheral devices
●
The control unit is supplied by the switched
mode power supply with 2 x 24 V dc and
with 13.5 V Peltier voltage.
●
For supplying the control logic, a voltage of
5 V is generated from the Peltier voltage.
Fig. 1
3
4
2
7 6 5
1
8
9
10