January 2001
5D - 5
Functions - Product Delivery
Service Manual Cafitesse 500
Fig. 5
Fig. 3
8
2
6
7
If necessary the cup carrier and the support
can now be replaced as follows:
●
Remove the cup carrier support (6) towards
the top. (Fig. 3)
●
Unscrew the support (7) from the splash
panel (2). (Fig. 4)
Mounting the cup stop / pot stop
●
Insert the cup stop (8) into the oval recess
in the cup carrier. (Fig. 5)
●
According to the cup size adjust the cup
stop (8) so that the cup is positioned
centrally underneath the outlet. (Fig. 5)
●
Install the pot stop on the drip grid so that
the pot is positioned centrally underneath
the outlet.
Fig. 4
7