January 2001
5A - 19
Functions - Water System
Service Manual Cafitesse 500
●
Disconnect the dispenser from the mains
supply and close the water supply valve.
●
Remove the boiler cover. (see pg. 5.A-7)
●
Remove the front part.
●
Loosen the screw at the splash panel and
open the splash panel by pressing it
downwards.
●
Dismount the hot water valve (1). (Fig. 1)
●
Remove the inner pipe bend (2) in the
interior of the boiler (5) from the
corresponding solenoid valve. (Fig. 1)
●
Remove the valve clamp (4) from the
sealing (3). (Fig. 1)
●
Remove the sealing (3). (Fig. 1)
●
Assembly is done in the reverse order.
●
When mounting, place the valve clamp on
the sealing and insert the valve with the
inner pipe bent into the sealing until it
engages in the valve clamp.
A.2.9
Disassembly of the Sealing Bush Boiler/Hot Water Valve
Fig. 1
5
2
1
4
3
Fig. 2
approx. 13mm
approx. 9mm
Outlet elbow for
hot water valve
Outlet elbow for
product valve
Outlet elbow for
hot water valve
Outlet elbow for
product valve