January 2001
5C - 5
Functions - Dosing System
Service Manual Cafitesse 500
C.2.2 Disassembly of the Motor for the Auto-Diaphragm
Fig. 1
●
Disconnect the dispenser from the power
supply and close the water supply valve.
●
Remove the brew basket, the combi-
trough and the trough box.
●
Remove the screws (4). Remove the
dummy cap (3) and the motor for the auto-
diaphragm (2). (Fig. 1)
●
Disconnect the electrical connection.
●
Dismount the lever arm (1). (Fig. 1)
During assembly mount the lever
arm at the new motor.
If the dummy cap is not provided with
holes when remounting, the holes must
be drilled in accordance with Fig. 2.
Fig. 2
0.85
0.22
0.26
1.07
0.24
0.24
2
3
4
1
2
1