January 2001
4 - 21
Programming
Service Manual Cafitesse 500
OTHER SETTINGS
●
Main menu: Select Other settings
Input
Ratio adjust=0X
0=dis, 1=enable
It is possible to change values.
0
=
It is not possible to change the
beverage strength by ±5 % on the
service panel.
1
=
It is possible to change the
beverage strength by ±5 % on the
service panel.
↓
Counter displ=##
0=dis, 1=enable
↓
Counter reset=0X
0=dis, 1=enable
This menu is only displayed if 'counter
display' is activated.
It is possible to change values.
0
=
It is not possible to reset the
counter on the Operating Panel
1
=
It is possible to reset the counter on
the Operating Panel.
↓
Use on/off when
empty ## 0=n, 1=y
0
=
The LED for the recognition of an
empty flexi-pack stops shining when
a new flexi-pack has been inserted
(= factory setting).
1
=
The LED for the recognition of an
empty flexi-pack stops shining when
a new flexi-pack has been inserted
and the dispenser has been
switched off and on again.
↓
Display temp?##
0=no, 1=yes
0
=
The cooling compartment temperature
is not indicated on the display.
1
=
The cooling compartment temperature
is indicated on the display alternatingly
with the ON/OFF status and a possible
malfunction indication.
Input
Other settings
---------------------------
BOILER SETTINGS
●
Main menu: Select Boiler settings
Input
Boiler temp=XX
Min:75 Max:95
It is possible to change values.
↓
Boiltemp lock=0X
0=dis, 1=enable
0
=
Beverage delivery at low
temperature in the boiler is enabled.
1
=
Beverage delivery at low
temperature in the boiler is blocked.
WARNING:
Pay attention to local
regulation (No sterilization,
danger of bacteria).
If the dispenser version code is chan-
ged while this function is selected,
0 = disable must be entered again.
1 = Beverage delivery at low
temperature in the boiler is
blocked.
Input