Installation / Putting into Operation
Service Manual Cafitesse 500
Customer
Recommendation:
Water supply line with shut off valve and
non-return valve.
Connection to hot water line only with
suitable supply lines.
Supply system
Temperature:
max. 167 °F
Dynamic pressure: min. 11.6 psi at
2.6 US gal/min
Static pressure:
max. 140 psi
Dispenser
Connections for hoses:
3/8 o.d. flare
Connecting pieces are included.
The dispenser must be installed with
adequate back flow protection that complies
with local regulations.
2.2.2 Water Supply
CAUTION:
Check the drinking water
quality before the installation.
A water filter must always be
installed.
CAUTION:
When using new water pipes,
flush them sufficiently before
the installation.
Read local regulations
carefully when choosing
supply lines. Only use neutral
material with respect to taste.