The B2 coils must be dismounted in the
following order:
-
Loosen the console for screened coil
-
Loosen the three outer screws (9) from
the mounting ring (6) through the slots in
the cooling compartment insulation and
completely remove the coil.
-
Remove the B2 coil (10) completely.
-
Remove the injection moulded empty
detection (11) from below from the
cooling compartment and replace them
completely. (Fig. 3)
ATTENTION:
Before mounting the new coil,
thermal compound must be
applied.
The sealing ring (12) must be replaced
in any case. (Fig. 4)
ATTENTION:
On the right-hand side ,
between B2 coil and cooling
compartment (13) there is an
insulating ring (14) with
equalizing ring (15). When
mounting, it must be observed
that insulating ring (14) and
equalizing ring (15) are
mounted correctly.
Fig. 3
10
9
6
11
11
12
15
14
13
Fig. 4