January 2001
5G - 2
Functions - Housing
Service Manual Cafitesse 500
G.2.1 Disassembly of the Housing Cover
●
Disconnect the dispenser from the mains
supply and close the water supply valve.
●
Loosen the locking rail (3) by turning the
screws (1) and remove the housing cover
(2) towards the top.
CAUTION:
When mounting, ensure that
the sealing (4) is installed
correctly. (Fig. 1)
When mounting a housing
cover with locking rail for the
first time in a housing without
slide-in unit, press the housing
cover tightly at the front and
close the locking rail (3) by
turning the screws (1). (Fig. 1)
Fig. 1
G
Housing
G.1 Adjustments
Not available
G.2 Disassemblies
4
1
1
3
2