January 2001
4 - 19
Programming
Service Manual Cafitesse 500
BUTTON SETTINGS FOR WATER BUTTON
●
Main menu: e.g. select settings for water
button
Settings for
Water button
Input
Button enable = 01
0=dis, 1=enable
Select 0 to disable the button
Select 1 to enable the button
↓
Volume=100cc
Min:40 Max:9999
For the hot water volume values between
40 cc and 9999cc can be entered.
↓
Dosing mode=01
0=CF 1=PC 2=REP
Select 0 for continuous flow (CF)
Select 1 for portion controlled delivery (PC)
Select 2 for constantly repeated portion (REP)
↓
Pause=00
Min:0 Max:20
For pause values between 0 and 20 can be
entered.
↓
Test dosing ?
Push 0
To start the test run see page 4-15.