20:1 Coffee/Tea Brewer Operation and Service Manual 

 

 

 
 
 
 
 

 

 

Model 

Height 

Width 

Depth 

US 

120 V 

Canada 

120 V 

240 V 

20:1-LD 

17.8 

8.5 

19.8 

1750W 

14.6A 

1400W 

11.7A 

3500W 

14.6A 

20:1-AP 

19.3 

8.5 

19.8 

1750W 

14.6A 

1400W 

11.7A 

3500W 

14.6A 

20:1-TD 

24.2 

8.5 

19.8 

1750W 

14.6A 

1400W 

11.7A 

3500W 

14.6A 

20:1-LP3 

17.3 

15.5 

18.4 

1700W 

14.2A 

1400W 

11.7A 

3800W 

17.1 

Model 20:1-AP 

Airpot not Included 

Summary of Contents for 20:1-LD

Page 1: ... Depth US 120 V Canada 120 V 240 V 20 1 LD 17 8 8 5 19 8 1750W 14 6A 1400W 11 7A 3500W 14 6A 20 1 AP 19 3 8 5 19 8 1750W 14 6A 1400W 11 7A 3500W 14 6A 20 1 TD 24 2 8 5 19 8 1750W 14 6A 1400W 11 7A 3500W 14 6A 20 1 LP3 17 3 15 5 18 4 1700W 14 2A 1400W 11 7A 3800W 17 1 Model 20 1 AP Airpot not Included ...

Page 2: ...ge circuit as indicated on the serial tag Turn power switch to the on position Brewer tank will begin to fill Once the tank is full the brewer will begin to heat Ready light will come on to indicate tank has finished heating CAUTION The water faucet will dispense hot water anytime the handle is pulled Programming 121753 firmware The 20 1 Brewer may be ordered as a standard coffee brewer or as a co...

Page 3: ...0 2500 In tens of gallons 50 500 gallons Increments are 500 gallons Power Mode nor nor SAV dn Normal Power Down or Power Save Power Down Save Time 4 00 OFF 0 30 4 00 Hours Minutes from last brew until brewer enters the selected power mode No effect if mode is Off Brew Counter 0 999 N A Shows number of brew cycles since last reset up to 999 Service Data Srv N A Used to view temperature probe data S...

Page 4: ...ings b1 N A Displays briefly to indicate that the parameters are for brew button 1 left Brew 1 Total Brew Volume 64 Off 30 128 Ounces Button can be turned off and will serve as cancel only Brew 1 Concentrate Volume 64 30 Total Brew Volume Program the volume of the total volume that should be delivered as hot water through basket Total Conc Cold Dilution Brew 1 Time 3 30 Min 9 59 Calculated minimum...

Page 5: ... run If a fault condition should occur the unit will display an error number as outlined below All errors may be reset by powering unit off and then back on Errors E1 and E2 are auto resetable and will clear themselves if the condition that caused them goes away E3 will disable the heater but will allow a brew cycle to complete The brewer will try to heat again when a brew cycle is started E4 and ...

Page 6: ...677 Thermistor probe dual temp 7 312 500404 Probe assy liquid level 90 deg 1 45 Labels 119978 Label faceplate red window 121479 Label faceplate blue window 401361 Label combo faceplate Regular Bold Tea 119996 Label set round icons 100254 Decal Hot Surfaces warning Flow controls 110305 Flow regulator PDS adjustable low 101350 Flow regulator diaphragm type 35 100298 Flow washer 35 GPM Baskets server...

Page 7: ...Man PN 121751 Rev 20170617 7 Wiring Diagram ...

Page 8: ... under this warranty by telephone at 800 556 3926 or by writing to 3650 New Town Blvd Saint Charles MO 63301 2 if requested by Newco shipping the defective equipment prepaid to an authorized Newco service location and 3 receiving prior authorization from Newco that the defective equipment is under warranty THE FOREGOING WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTY WRITTEN OR ORAL EXP...

Reviews: