Service Mode

 is entered by holding any two of the buttons on the face of the machine while powering up the brewer.  

The brewer firmware revision number is displayed for a couple of seconds when entering this mode.  The table below 
list the items that may be programmed along with available values or settings.  Use the center brew button to 
advance through the items and the left and right button to decrement or increment the values/selection respectively.  
These items are programmed at the factory and will typically not need adjustment.  For coffee only brewers (no 2

nd

 

valve) ignore the dilution calibration and cold calibration volume.  Use the center button to advance through those 
items. 
 

Item Selected 

Screen 

Example 

Values 

Available 

Comment 

Water Temperature 

200 

170-205 

Degrees F 

Pulse Heating 
New in version 2 of 
121753 control board 

Off 

On, OFF 

Must be OFF for mechanical relay.  May be on or off for solid 
state relay, on is preferred.  If brewer has a heat sink on the 
back, this indicates it has a solid state relay for tank heater.  

End of Cycle Beeper 

On 

On, OFF 

Used to audibly indicate brew cycle has completed with a 
series of beeps. 

Brew Pump Speed 

b:05 

1-10 

Pump speed used for brewing 

Not Used 

F:05 

2-10 

No effect.  Unused feature. 

Pump Calibration 

CAL 

N/A 

See instructions below.  

Must be done if pump speed 

modified.

 

Hot Calibration Vol 

39.0 

25.0-99.9 

Ounces.  Only displays if calibration cycle was run. 

Dilution Calibration 

CLd 

N/A 

Press left or right button to run dilution valve calibration. 

Cold Calibration Vol 

24 

20-150 

Ounces delivered during cold water dilution. 

Water Fill Flow Rate 

0.30 

Off, 0.05-1.40  Adjustable in increments of .05 GPM.  Should match flow rate 

through valve. 

Water Filter Capacity 

100 

Off, 500-2500  In tens of gallons.  50=500 gallons. Increments are 500 

gallons. 

Power Mode 

nor 

nor, SAV, dn 

Normal, Power Down, or Power Save. 

Power Down/Save 
Time 

4:00 

OFF, 0:30-

4:00 

Hours:Minutes from last brew until brewer enters the selected 
power mode.  No effect if mode is “Off”. 

Brew Counter 

0-999 

N/A 

Shows number of brew cycles since last reset (up to 999). 

Service Data 

Srv 

N/A 

Used to view temperature & probe data.  See 

Service Data

 

below. 

Exit 

End 

N/A 

Use left or right button when displayed to exit this mode. 

 
Pump Calibration: 
 
Pump calibration is necessary when the pump speed is changed or if the brewer is delivering substantially more or 
less beverage than what it has been programmed for in the user mode.  Pump speed may be adjusted up or down if 
required to deliver water at a faster or slower rate to meet a specific beverage taste profile.  Calibration tells the 
brewer control how much hot water is delivered within a specific time frame so it can adjust the time required to run 
to deliver the desired brew volumes. 

 

Ensure the brew basket is in place.  Place a suitably graduated container in place below the brew basket to capture 
and measure the water delivered.  To calibrate, enter the service mode as noted above and advance to the “CAL” 
screen.  Press either the left or right brew button and water delivery will begin.  If the brewer has not reached 
operating temperature, it will finish heating before automatically starting.  The pump will cycle on and off for 
approximately 2 minutes at which time the currently programmed volume is displayed.  Use the left and right button 
to decrement or increment the value to the measured value.  For better accuracy, you may want to measure a couple 
of cycles and average the measured values.  At the least, the system should be primed before calibration by allowing 
a partial brew cycle to run (10-15 secs).   
 

Note: User mode will be entered automatically when exiting the service mode if calibration values have been 
changed. 

 

 

 

Summary of Contents for 20:1-LD

Page 1: ... Depth US 120 V Canada 120 V 240 V 20 1 LD 17 8 8 5 19 8 1750W 14 6A 1400W 11 7A 3500W 14 6A 20 1 AP 19 3 8 5 19 8 1750W 14 6A 1400W 11 7A 3500W 14 6A 20 1 TD 24 2 8 5 19 8 1750W 14 6A 1400W 11 7A 3500W 14 6A 20 1 LP3 17 3 15 5 18 4 1700W 14 2A 1400W 11 7A 3800W 17 1 Model 20 1 AP Airpot not Included ...

Page 2: ...ge circuit as indicated on the serial tag Turn power switch to the on position Brewer tank will begin to fill Once the tank is full the brewer will begin to heat Ready light will come on to indicate tank has finished heating CAUTION The water faucet will dispense hot water anytime the handle is pulled Programming 121753 firmware The 20 1 Brewer may be ordered as a standard coffee brewer or as a co...

Page 3: ...0 2500 In tens of gallons 50 500 gallons Increments are 500 gallons Power Mode nor nor SAV dn Normal Power Down or Power Save Power Down Save Time 4 00 OFF 0 30 4 00 Hours Minutes from last brew until brewer enters the selected power mode No effect if mode is Off Brew Counter 0 999 N A Shows number of brew cycles since last reset up to 999 Service Data Srv N A Used to view temperature probe data S...

Page 4: ...ings b1 N A Displays briefly to indicate that the parameters are for brew button 1 left Brew 1 Total Brew Volume 64 Off 30 128 Ounces Button can be turned off and will serve as cancel only Brew 1 Concentrate Volume 64 30 Total Brew Volume Program the volume of the total volume that should be delivered as hot water through basket Total Conc Cold Dilution Brew 1 Time 3 30 Min 9 59 Calculated minimum...

Page 5: ... run If a fault condition should occur the unit will display an error number as outlined below All errors may be reset by powering unit off and then back on Errors E1 and E2 are auto resetable and will clear themselves if the condition that caused them goes away E3 will disable the heater but will allow a brew cycle to complete The brewer will try to heat again when a brew cycle is started E4 and ...

Page 6: ...677 Thermistor probe dual temp 7 312 500404 Probe assy liquid level 90 deg 1 45 Labels 119978 Label faceplate red window 121479 Label faceplate blue window 401361 Label combo faceplate Regular Bold Tea 119996 Label set round icons 100254 Decal Hot Surfaces warning Flow controls 110305 Flow regulator PDS adjustable low 101350 Flow regulator diaphragm type 35 100298 Flow washer 35 GPM Baskets server...

Page 7: ...Man PN 121751 Rev 20170617 7 Wiring Diagram ...

Page 8: ... under this warranty by telephone at 800 556 3926 or by writing to 3650 New Town Blvd Saint Charles MO 63301 2 if requested by Newco shipping the defective equipment prepaid to an authorized Newco service location and 3 receiving prior authorization from Newco that the defective equipment is under warranty THE FOREGOING WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTY WRITTEN OR ORAL EXP...

Reviews: