GENERAL DESCRIPTION

The Sub-Zero SZ-7510-C are aesthetically superior versions 
of  their  predecessors.  The  SZ-7510-C  is  a  single  set  point 
controller.  It  is  specifically  designed  for  refrigeration 
applications wherein the compressor cuts off at set point and is 
restarted at a temperature of set point plus differential.

Additionally these controllers offer several protection features 
that are easily understood by the examples in the instructions 
below.  The  controller  can  be  used  for  heating  applications, 
when the P1 parameter is set to “1” 

A number of parameters are displayed alphanumerically to set 
up the instrument for each specific application.

The SZ-7510-C controller can be used for several applications 

O

O

with a measuring range from -50.0 C to 50.0 C.

Instructions

 

: SZ-7510-C

INDEX

Para. Page

Description

To set the SET Point of the controller.
How to set other parameters.
To set Heating or Cooling function.
Max High Temp limit & alarm.
Min Low Temp limit & alarm.
To set Differential (Hysterisis).
Probe calibration.
Time Delay (relay restart after cutoff).
Keypad lock.
Relay status on probe failure.
To enable/disable power switch.
Unit ID.
Restore factory defaults.
End Programming.
Operating messages.
Technical Data.
Wiring diagram.
Panel cutout & dimensions.

P1
P2
P3
P4
P5
P6
LP
E1

PO

ID

FS
EP

3
4
5
6
7
8
9

10
11
12
13
14
15
16
17
18
19

20-21

2

INDIA

To set other
Parameters

Display will show P1 & scroll 
description of parameter.
To go to other parameters,
use UP/DOWN  keys.

Press & hold
the DOWN(prg)
key for 
2 seconds. 

prg

Function : T
the controller.

o set the cut out point of 

Display  will  show  SET  &  scroll 
description  of  parameter.  The  set 
point value can now be changed by 
using  the  UP/DOWN  key.  After 
setting the desired value, press the 
set key and you will see “- - -” which 
confirms that the set point has been 
stored in memory.

Set point

Press and
the SET
key for 
2 Seconds.

 hold

P3 -0.5 P2 +0.5

0.0

O

C

Min

Max

Fac.

3

SET

Changes : 12Vac/dc Wiring Diagram Added

Summary of Contents for SZ-7510-C

Page 1: ...e SET Point of the controller How to set other parameters To set Heating or Cooling function Max High Temp limit alarm Min Low Temp limit alarm To set Differential Hysterisis Probe calibration Time Delay relay restart after cutoff Keypad lock Relay status on probe failure To enable disable power switch Unit ID Restore factory defaults End Programming Operating messages Technical Data Wiring diagra...

Page 2: ...ge the P6 parameter press the SET key Min Max Fac Use UP DOWN keys to set desired value This parameter is used to protect the compressor from restarting in a short period of time and can be set between 0 to 20 minutes Example If this parameter is set at 3 minutes the relay will cut off at the set temperature but will not restart for a minimum of 3 minutes even if the differential is achieved earli...

Page 3: ...h ENB Enables power switch Controller has power switch which if enable puts controller in active or stand by state If press for 2 seconds controller will go in stand by mode display will show OF To again switch to ACTIVE WORKING MODE press power switch again for 2 seconds All leds and 7 segment display will flash and enter into NORMAL WORKING MODE 14 ID Parameter Function To set unit ID 1 240 1 Mi...

Page 4: ...echnical data Dimensions Front 75 X 34 5 MM Depth 71 MM w o back lid Panel Cutout 29 X 71 mm Mounting Flush panel mounting with fasteners Frontal protection I P65 Connections Screw terminal blocks 2 5sqmm one wire terminal only Display 3 X17 mm 0 67 LED Data storage Non volatile EEPROM memory Power input 230Vac 15 50 60Hz Other on request O O Operating temp 5 C to 50 C non condensing O O Storage t...

Page 5: ...rreparable damage and personal injury Kindly ensure that wiring is done by qualified personnel only Maintenance Cleaning Clean the surface of the controller with a soft moist cloth Do not use abrasive detergents petrol alcohol or solvents Notice The information in this document is subject to change in order to improve reliability design or function without prior notice and does not represent a com...

Reviews: