11
LP
Parameter
NO
YES
NO
Function : To lock keypad.
To change
the LP
parameter
press the
SET key.
Use UP/DOWN keys to set desired
value.
This parameter can lock the keypad
so that tampering is not possible by
by-standers.
NO = keypad unlocked
YES = keypad locked
When locked all parameters can
only be viewed, but not modified.
Min
Max
Fac.
12
E1
Parameter
ON
OFF
CYC
Function : Relay status on
Probe Failure.
Min
Max
Fac.
To change
the E1
parameter
press the
SET key.
Use UP/DOWN keys to set desired
value.
When set to
ON = Relay status is ON.
CYC = Relay performs duty cycle of
10 minutes ON and 4minutes
OFF.
OFF = Relay status is OFF.
13
PO
Parameter
Function : To enable/disable Power
Switch
DIS
ENB
DIS
Min
Max
Fac.
To change
the PO
parameter
press the
SET key.
Use UP/DOWN keys to get desired
value & press SET key to confirm.
DIS = Disable power switch
ENB= Enables power switch
Controller has power switch, which
if enable puts controller in active or
stand by state.
If press for 2 seconds controller will
go in stand by mode, display will
show “OF”
To again switch to ACTIVE
WORKING MODE, press power
switch again for 2 seconds. All
leds and 7-segment display will flash
and enter into NORMAL WORKING
MODE.
14
ID
Parameter
Function : To set unit ID.
1
240
1
Min
Max
Fac.
To change
the ID
parameter
press the
SET key.
Use UP/DOWN keys to get desired
value & press SET key to confirm.
With this parameter one can set the
unit ID of the device.
15
FS
Parameter
Function : To restore default
settings of the controller.
NO
YES
NO
Min
Max
Fac.
To change
the FS
parameter
press the
SET key.
When set to ‘YES’ all parameters
are programmed to factory
values.
Useful to debug setting
related problems.
16
EP
Parameter
To end
programming
press the
SET key.
Once the
key is pressed, the
control goes into the normal mode
and displays the temperature and
all settings are recorded.
SET
Function: To end programming.