Bit Hex
Dec
Ext. status word
Ext. status word 2
Ext. status
word 3
Parameter 16-94 Ext. Status Word
Parameter 16-95 Ext.
Status Word 2
Parameter
16-99 Ext.
Status Word 3
speed <
parameter 4-52 Warning Speed Low
11
00000800 2048
Brake check OK
brake test NOT OK
Stop
–
12
00001000 4096
Braking max.
BrakePower > Brakepowerlimit (2-12)
Standby
–
13
00002000 8192
Braking
Freeze output re-
quest
–
14
00004000 16384
Out of speed range
Freeze output
–
15
00008000 32768
OVC active
Jog request
–
16
00010000 65536
AC brake
Jog
–
17
00020000 131072
Password timelock
number of allowed password trials exceeded - timelock
active
Start request
–
18
00040000 262144
Password protection
0-61 = ALL_NO_ACCESS OR
BUS_NO_ACCESS OR
BUS_READONLY
Start
–
19
00080000 524288
Reference high
reference >
parameter 4-55 Warning Reference High
Start applied
–
20
00100000 1048576
Reference low
reference <
parameter 4-54 Warning Reference Low
Start delay
–
21
00200000 2097152
Local reference
reference site = REMOTE -> auto on pressed & active
Sleep
–
22
00400000 4194304
Protection mode notification
Sleep boost
–
23
00800000 8388608
Unused
Running/pipe filling
–
24
01000000 16777216
Unused
Drive bypass
–
25
02000000 33554432
Unused
Emergency mode
–
26
04000000 67108864
Unused
External interlock
–
27
08000000 134217728
Unused
Emerg. m limit excee-
ded
–
28
10000000 268435456
Unused
FlyStart active
–
AU275636650261en-000101 / 130R0334 | 699
Danfoss A/S © 2022.12
Troubleshooting
VLT AutomationDrive FC 301/302
Programming Guide