Option
Name
Description
[3462]
Program status
[3464]
MCO 302 status
[3465]
MCO 302 control
[3466]
SPI error counter
[3470]
MCO alarm word 1
[3471]
MCO alarm word 2
[4029]
B-EMF protection log readout
[4280]
Safe option status
[4285]
Active safe func.
[4521]
Status
[4523]
Baseline failure
[4590]
Stator [%]
[4591]
Load [%]
[4592]
Sensor 1 [%]
[4593]
Sensor 1 [unit]
[4594]
Sensor 2 [%]
[4595]
Sensor 2 [unit]
[4596]
Sensor 3 [%]
[4597]
Sensor 3 [unit]
[4598]
Sensor 4 [%]
[4599]
Sensor 4 [unit]
Parameter 9-18 Node Address
Table 546: Parameter 9-18 Node Address
9-18 Node Address
Default value: 126
Parameter type: Range, 1 - size related
Setup: 1 setup
Conversion index: 0
Data type: Uint8
Change during operation: True
Enter the station address in this parameter or, alternatively, in the hardware switch. To adjust the station address in this parameter,
set the hardware switch to 126 or 127 (that is all switches set to ON). Otherwise, this parameter shows the actual setting of the
switch.
Parameter 9-19 Drive Unit System Number
Table 547: Parameter 9-19 Drive Unit System Number
9-19 Drive Unit System Number
Default value: 1034
Parameter type: Range, 0 - 65535
Setup: All setups
Conversion index: 0
Data type: Uint16
Change during operation: True
AU275636650261en-000101 / 130R0334 | 311
Danfoss A/S © 2022.12
Parameter Descriptions
VLT AutomationDrive FC 301/302
Programming Guide