Option Name
Description
[166]
Relay 7
[167]
Relay 8
[168]
Relay 9
[180]
Local reference ac-
tive
Active when
parameter 3-13 Reference Site
is
[2] Local
or when
parameter 3-13 Reference Site
is
[0] Linked to hand/auto
, at the same time as the LCP is in hand-on mode.
[181]
Remote reference
active
Active when
parameter 3-13 Reference Site
is
[1] Remote
or
[0] Linked to hand/auto
, while the LCP
is in auto-on mode.
[182]
Start command
Active when there is an active start command and no stop command.
[183]
Drive stopped
A stop command (jog, stop, qstop, coast) is issued – and not from the SLC itself.
[185]
Drive in hand mode
Active when the drive is in hand-on mode.
[186]
Drive in auto mode
Active when the drive is in auto-on mode.
[187]
Start command giv-
en
[190]
Digital input X30/2
[191]
Digital input X30/3
[192]
Digital input X30/4
[193]
Digital input X46/1
[194]
Digital input X46/3
[195]
Digital input X46/5
[196]
Digital input X46/7
[197]
Digital input X46/9
[198]
Digital input X46/11
[199]
Digital input X46/13
[212]
Emergency mode
[222]
Homing OK
N O T I C E
This option is only available with software version 48.2X and newer.
Homing is completed with the selected homing function (
parameter 17-80 Homing Function
).
[223]
On target
N O T I C E
This option is only available with software version 48.2X and newer.
Positioning is completed and the on-target signal is sent when the actual position is within
parameter 3-05 On Reference Window
for the duration of
parameter 3-09 On Target Time
and the
actual speed does not exceed
parameter 3-05 On Reference Window
.
AU275636650261en-000101 / 130R0334
386 | Danfoss A/S © 2022.12
Parameter Descriptions
VLT AutomationDrive FC 301/302
Programming Guide