Parameter 33-95 X60 MCO RS485 Serial Baud Rate
Table 1238: Parameter 33-95 X60 MCO RS485 Serial Baud Rate
33-95 X60 MCO RS485 Serial Baud Rate
Default value: [2] 9600 Baud
Parameter type: Option
Setup: 2 setups
Conversion index: -
Data type: Uint8
Change during operation: True
Option
Name
Description
[0]
2400 Baud
[1]
4800 Baud
[2]*
9600 Baud
[3]
19200 Baud
[4]
38400 Baud
[5]
57600 Baud
[6]
76800 Baud
[7]
115200 Baud
5.27 Parameter Group 34-** MCO Data Readouts
Parameters in this group are available when VLT® Motion Control Option MCO 305 is installed in the drive. For information about
the option, refer to VLT® Motion Control Option MCO 302 Operating Instructions.
5.27.1 34-0* PCD Write Par.
Parameter 34-01 PCD 1 Write to MCO
Table 1239: Parameter 34-01 PCD 1 Write to MCO
34-01 PCD 1 Write to MCO
Default value: 0
Parameter type: Range, 0 - 65535
Setup: All setups
Conversion index: 0
Data type: Uint16
Change during operation: True
Shows the value received in PCD1 of the fieldbus telegram.
Parameter 34-02 PCD 2 Write to MCO
Table 1240: Parameter 34-02 PCD 2 Write to MCO
34-02 PCD 2 Write to MCO
Default value: 0
Parameter type: Range, 0 - 65535
Setup: All setups
Conversion index: 0
Data type: Uint16
Change during operation: True
Shows the value received in PCD2 of the fieldbus telegram.
Parameter 34-03 PCD 3 Write to MCO
Table 1241: Parameter 34-03 PCD 3 Write to MCO
34-03 PCD 3 Write to MCO
Default value: 0
Parameter type: Range, 0 - 65535
Setup: All setups
Conversion index: 0
Data type: Uint16
Change during operation: True
AU275636650261en-000101 / 130R0334
624 | Danfoss A/S © 2022.12
Parameter Descriptions
VLT AutomationDrive FC 301/302
Programming Guide