N O T I C E
This parameter cannot be adjusted while the motor is running.
N O T I C E
Set digital input to
[0] PNP - Active at 24 V
in
parameter 5-00 Digital I/O Mode
.
N O T I C E
When using VLT® PTC Thermistor Card MCB 112 always always select
[0] None
.
Select the input to which the thermistor (PTC sensor) should be connected. An analog input option
[1] Analog Input 53
or
[2] Analog
Input 54
cannot be selected if the analog input is already in use as a reference source (selected in
parameter 3-15 Reference Resource
1
,
parameter 3-16 Reference Resource 2
, or
parameter 3-17 Reference Resource 3
).
Option
Name
Description
[0]*
None
[1]
Analog input 53
[2]
Analog input 54
[3]
Digital input 18
[4]
Digital input 19
[5]
Digital input 32
[6]
Digital input 33
Parameter 1-94 ATEX ETR Cur. Lim. Speed Reduction
Table 139: Parameter 1-94 ATEX ETR Cur. Lim. Speed Reduction
1-94 ATEX ETR Cur. Lim. Speed Reduction
Default value: 0%
Parameter type: Range, 0 - 100%
Setup: 2 setups
Conversion index: -1
Data type: Uint16
Change during operation: True
Only visible if
parameter 1-90 Motor Thermal Protection
is set to
[20] ATEX ETR
.
Configure the reaction for operating in Ex-e current limit. 0%: The drive does not change anything besides issuing
warning 163, ATEX
ETR cur.lim.warning
. >0%: The drive issues
warning 163, ATEX ETR cur.lim.warning
and reduces motor speed following ramp 2 (
param-
eter group 3-5* Ramp 2
).
Example:
Actual reference = 50 RPM
Parameter 1-94 ATEX ETR cur.lim. speed reduction
= 20%
Resulting reference = 40 RPM
Parameter 1-95 Thermistor Sensor Type
Table 140: Parameter 1-95 Thermistor Sensor Type
1-95 Thermistor Sensor Type
Default value: [0] KTY Sensor 1
Parameter type: Option
Setup: All setups
Conversion index: –
Data type: Uint8
Change during operation: True
Select the used type of thermistor sensor.
AU275636650261en-000101 / 130R0334
104 | Danfoss A/S © 2022.12
Parameter Descriptions
VLT AutomationDrive FC 301/302
Programming Guide