Option
Name
Description
[0]*
Encoder Z positive
[1]
Encoder Z negative
[2]
Ext. marker positive
[3]
Ext. marker negative
Parameter 33-21 Master Marker Tolerance Window
Table 1183: Parameter 33-21 Master Marker Tolerance Window
33-21 Master Marker Tolerance Window
Default value: 0
Parameter type: Range, 0 - 1073741823
Setup: 2 setups
Conversion index: 0
Data type: Uint32
Change during operation: True
Parameter 33-22 Slave Marker Tolerance Window
Table 1184: Parameter 33-22 Slave Marker Tolerance Window
33-22 Slave Marker Tolerance Window
Default value: 0
Parameter type: Range, 0 - 1073741823
Setup: 2 setups
Conversion index: 0
Data type: Uint32
Change during operation: True
Parameter 33-23 Start Behavior for Marker Sync
Table 1185: Parameter 33-23 Start Behavior for Marker Sync
33-23 Start Behavior for Marker Sync
Default value: [0] Leading marker
Parameter type: Option
Setup: 2 setups
Conversion index: -
Data type: Uint16
Change during operation: True
Option
Name
Description
[0]*
Leading marker
[1]
Following marker
[2]
Closest marker
[3]
Master vel/ldg mrk
[4]
Master vel/flw mrk
[5]
Master vel/cls mrk
[6]
Next 2 markers
[7]
Start with poly5
[1000]
Ldg mrk late offs
[1001]
Flw mrk late offs
[1002]
Cls mark late offs
[1003]
Mv/ldg mrk/lt off
[1004]
Mv/flw mrk/lt off