Option Name
Description
[30]
Set vir. mas. pos.
to actual
N O T I C E
This option is only available with software version 48.XX.
Bit for setting the virtual master position = the actual follower position. This is needed for setting
the correct starting position for position-controlled virtual master ensuring that the virtual master
ensuring that the virtual master position is aligned with the physical position of the follower.
[31]
Activate CAM ta-
ble
N O T I C E
This option is only available with software version 48.XX.
Signal for activating a new CAM table while running with bumpless transfer.
[32]
Halt
[33]
Bit 10 = 0 > CTW
TO always
[78]
Reset preventive
maintenance
word
[94]
Light load detec-
tion
Use this option to ensure drive runs in the direction which requires least energy (UPS capacity),
during an emergency.
[95]
Evacuation mode
Use this function to operate the drive at reduced DC voltage for evacuating people in case of pow-
er failure.
[189]
Emergency mode
[190]
Emcy mode ref bit
0
Enables a choice between 1 of the 8 preset references.
[191]
Emcy mode ref bit
1
Enables a choice between 1 of the 8 preset references.
[192]
Emcy mode ref bit
2
Enables a choice between 1 of the 8 preset references.
[195]
Test emcy mode
Emergency mode is activated in a special test mode where the drive stops on all alarms.
[231]
Power limit mot.
N O T I C E
This option is only available in FC 302.
See
parameter group 4-8* Power Limit
. Use this option in the motor mode only.
[232]
Power limit gen.
N O T I C E
This option is only available in FC 302.
See
parameter group 4-8* Power Limit
. Use this option in the generating mode only.
AU275636650261en-000101 / 130R0334
282 | Danfoss A/S © 2022.12
Parameter Descriptions
VLT AutomationDrive FC 301/302
Programming Guide