Bit
0
1
13
Set-up select LSB
–
14
Set-up select MSB
–
15
No reversing
Reversing
1
Different from
[0] FC Profile
. Options for bits 0–2, and 12–15 in
parameter 8-14 Configurable Control Word CTW
:
[11] Start Homing
[12] Activate Touch Probe
[13] Sync. to Pos. Mode
[14] Ramp 2
[15] Relay 1
[16] Relay 2
[17] Speed Mode
[18] Start Virtual Master
[19] Activate Master Offset
[21] Target Inverse
[26] Home Sensor
[27] Touch Sensor
[28] Position Vir. Master
[29] Set Master Home
[30] Set Vir. Mas. Pos. to Actual
[31] Activate CAM Table
Table 1433: Status Word
Bit
0
1
0
Control not ready
Control ready
1
Drive not ready
Drive ready
2
Coasting
Enable
3
No error
Trip
4
(1)
Not homed
Home done
5
Reserved
Reserved
6
No error
Trip lock
7
No warning
Warning
8
(1)
Not on target position
Target position reached
9
Local operation
Bus control
10
Out of frequency limit
Frequency limit OK
11
No operation
In operation
12
Drive OK
Stopped, auto start
AU275636650261en-000101 / 130R0334 | 689
Danfoss A/S © 2022.12
Integrated Motion Controller
VLT AutomationDrive FC 301/302
Programming Guide