Parameter 15-98 Drive Identification
Table 820: Parameter 15-98 Drive Identification
15-98 Drive Identification
Default value: 0
Parameter type: Range, 0 - 40
Setup: All setups
Conversion index: 0
Data type: VisStr[40]
Change during operation: False
This parameter contains data used by the VLT® Motion Control Tool MCT 10.
Parameter 15-99 Parameter Metadata
Table 821: Parameter 15-99 Parameter Metadata
15-99 Parameter Metadata
Default value: 0
Parameter type: Range, 0 - 9999, Array [35]
Setup: All setups
Conversion index: 0
Data type: Uint16
Change during operation: False
This parameter contains data used by the VLT® Motion Control Tool MCT 10.
5.16 Parameter Group 16-** Data Readouts
5.16.1 16-0* General Status
Parameter 16-00 Control Word
Table 822: Parameter 16-00 Control Word
16-00 Control Word
Default Value: 0
Parameter Type: Range, 0 - 65535
Setup: All setups
Conversion Index: 0
Data Type: V2
Change during operation: False
View the control word sent to the drive via the serial communication port in hex code.
Parameter 16-01 Reference [Unit]
Table 823: Parameter 16-01 Reference [Unit]
16-01 Reference [Unit]
Default value: 0 ReferenceFeedbackU-
nit
Parameter type: Range, -999999 ReferenceFeedback-
Unit - 999999 ReferenceFeedbackUnit
Setup: All setups
Conversion index: -3
Data type: Int32
Change during operation: False
View the present reference value applied on impulse or analog basis in the unit resulting from the configuration selected in
parame-
ter 1-00 Configuration Mode
(Hz, Nm, or RPM).
Parameter 16-02 Reference %
Table 824: Parameter 16-02 Reference %
16-02 Reference %
Default value: 0%
Parameter type: Range, -200 - 200%
Setup: All setups
Conversion index: -1
Data type: Int16
Change during operation: False
View the total reference. The total reference is the sum of digital, analog, preset, bus, and freeze references plus catch up and slow
down.
AU275636650261en-000101 / 130R0334
496 | Danfoss A/S © 2022.12
Parameter Descriptions
VLT AutomationDrive FC 301/302
Programming Guide
Summary of Contents for VLT AutomationDrive FC 301