Option
Name
Description
[126]
ft
3
/min
[127]
ft
3
/h
[130]
lb/s
[131]
lb/min
[132]
lb/h
[140]
ft/s
[141]
ft/min
[145]
ft
[150]
lb ft
[160]
°F
[170]
psi
[171]
lb/in
2
[172]
in WG
[173]
ft WG
[176]
kpsi
[177]
MPa
[178]
kBar
[180]
HP
Parameter 24-03 Emergency Mode Min Reference
Table 1040: Parameter 24-03 Emergency Mode Min Reference
24-03 Emergency Mode Min Reference
Default value: Size related Parameter type: Range, -999999.999 - par. 24-04 EmergencyMode-
MaxReference
Setup: All setups
Conversion index: -3
Data type: Int32
Change during operation: True
Minimum value to the reference/setpoint (limiting the sum of values in
parameter 24-05 Emergency Mode Preset Reference
and value
of signal on input selected in
parameter 24-06 Emergency Mode Reference Source
). If running in open loop when emergency mode is
active, the unit is selected by the setting
parameter 0-02 Motor Speed Unit
. For closed loop, select the unit in
parameter 24-02 Emer-
gency Mode Unit
.
Parameter 24-04 Emergency Mode Max Reference
Table 1041: Parameter 24-04 Emergency Mode Max Reference
24-04 Emergency Mode Max Reference
Default value: Size related Parameter type: Range, par. 24-03 - 999999.999 EmergencyMode-
MinReference
Setup: All setups
Conversion index: -3
Data type: Int32
Change during operation: True
AU275636650261en-000101 / 130R0334
566 | Danfoss A/S © 2022.12
Parameter Descriptions
VLT AutomationDrive FC 301/302
Programming Guide