N O T I C E
A power cycle is necessary after setting the IP parameters manually.
This parameter is read-only. It shows the IP address of the found DHCP or BOOTP server.
Parameter 12-05 Lease Expires
Table 608: Parameter 12-05 Lease Expires
12-05 Lease Expires
Default value: Size related
Parameter type: Range, Size related
Setup: All setups
Conversion index: 0
Data type: TimeDifferenceWithDateIndication
Change during operation: True
This parameter is read-only. It shows the lease time for the current DHCP-assigned IP address.
Parameter 12-06 Name Servers
Table 609: Parameter 12-06 Name Servers
12-06 Name Servers
Default value: 0
Parameter type: Range, 0 -4294967295
Setup: All setups
Conversion index: 0
Data type: OctetString
Change during operation: True
IP addresses of the domain name servers. Can be automatically assigned when using DHCP.
Parameter 12-07 Domain Name
Table 610: Parameter 12-07 Domain Name
12-07 Domain Name
Default value: 0
Parameter type: Range, 0 - 48
Setup: 1 setup
Conversion index: 0
Data type: VisibleString
Change during operation: True
Domain name of the attached network. Can be automatically assigned when using DHCP network.
Parameter 12-08 Host Name
Table 611: Parameter 12-08 Host Name
12-08 Host Name
Default value: 0
Parameter type: Range, 0 - 48
Setup: 1 setup
Conversion index: 0
Data type: VisibleString
Change during operation: True
Logical (given) name of the option.
N O T I C E
The display of the drive only shows the 1
st
19 characters, but the remaining characters are stored in the drive. If hardware
switches are different from all ON or all OFF, the switches have priority.
Parameter 12-09 Physical Address
Table 612: Parameter 12-09 Physical Address
12-09 Physical Address
Default value: 0
Parameter type: Range, 0 - 17
Setup: 1 setup
Conversion index: 0
Data type: VisibleString
Change during operation: True
AU275636650261en-000101 / 130R0334 | 349
Danfoss A/S © 2022.12
Parameter Descriptions
VLT AutomationDrive FC 301/302
Programming Guide