Parameter 16-41 Performance Maintenance
Table 859: Parameter 16-41 Performance Maintenance
16-41 Performance Maintenance
Default value: 0
Parameter type: Range, 0 - 2147483647
Setup: All setups
Conversion index: 0
Data type: VisStr[50]
Change during operation: True
Parameter 16-42 Service Log Counter
Table 860: Parameter 16-42 Service Log Counter
16-42 Service Log Counter
Default value: 0
Parameter type: Range, 0 - 24
Setup: All setups
Conversion index: 0
Data type: Uint8
Change during operation: True
Shows the number of service logs stored in the ServiceLog file. If the ServiceLog file is full, clear the logged data by selecting option
[5] Clear
service logs in
parameter 14-22 Operation Mode
. The logged data is deleted on the next power-up.
Parameter 16-43 Timed Actions Status
Table 861: Parameter 16-43 Timed Actions Status
16-43 Timed Actions Status
Default value: [0] Timed actions auto
Parameter type: Option
Setup: All setups
Conversion index: -
Data type: Uint8
Change during operation: True
Select the times actions view.
Option
Name
Description
[0]*
Timed actions auto
[1]
Timed actions disabled
[2]
Constant on action
[3]
Constant off actions
Parameter 16-44 Speed Error [RPM]
Table 862: Parameter 16-44 Speed Error [RPM]
16-44 Speed Error [RPM]
Default value: 0 RPM
Parameter type: Range, -30000 - 30000 RPM
Setup: All setups
Conversion index: 67
Data type: Int32
Change during operation: True
N O T I C E
This parameter is only available with software version 48.XX.
Shows the difference between the speed reference and the actual speed.
AU275636650261en-000101 / 130R0334
504 | Danfoss A/S © 2022.12
Parameter Descriptions
VLT AutomationDrive FC 301/302
Programming Guide