Option Name
Description
[233]
Power limit both
N O T I C E
This option is only available in FC 302.
See
parameter group 4-8* Power Limit
. Use this option in both the motor and the generating
modes.
[234]
Light load+evacu-
ation
N O T I C E
This option is only available in FC 302.
Use this option to ensure that the drive runs in the direction which requires least energy (UPS ca-
pacity), during an emergency and to operate the drive at reduced DC-voltage for evacuating peo-
ple in case of power failure.
[235]
Setup bit 0
[236]
Setup bit 1
Parameter 8-17 Configurable Alarm and Warning Word
Table 506: Parameter 8-17 Configurable Alarm and Warningword
8-17 Configurable Alarm and Warningword
Default value: [0] Off
Parameter type: Option, Array [16]
Setup: All setups
Conversion index: –
Data type: Uint16
Change during operation: True
The configurable alarm and warning word has 16 bits (0–15). Each of those bits can be configured to any of the following options.
Option
Name
Description
[0]*
Off
[1]
10 Volts low warning
[2]
Live zero warning
[3]
No motor warning
[4]
Mains phase loss warning
[5]
DC link voltage high warning
[6]
DC link voltage low warning
[7]
DC overvoltage warning
[8]
DC undervoltage warning
[9]
Inverter overloaded warning
[10]
Motor ETR overtemp warning
[11]
Motor thermistor overtemp warning
[12]
Torque limit warning
[13]
Over current warning
AU275636650261en-000101 / 130R0334 | 283
Danfoss A/S © 2022.12
Parameter Descriptions
VLT AutomationDrive FC 301/302
Programming Guide