
N O T I C E
This parameter is only available with software version 48.XX.
Set the master home position in position units which are used by master homing function.
5.17.9 17-9* Position Configuration
Parameter 17-90 Absolute Position Mode
Table 959: Parameter 17-90 Absolute Position Mode
17-90 Absolute Position Mode
Default value: [0] Standard
Parameter type: Option
Setup: All setups
Conversion index: -
Data type: Uint8
Change during operation: False
N O T I C E
This parameter is only available with software version 48.XX.
Select the behavior when executing consecutive absolute positioning commands.
Option Name
Description
[0]*
Standard When the drive receives a new absolute positioning command while the previous command is still in pro-
gress, it executes the new positioning command immediately without completing the previous position-
ing.
[1]
Buffered
When the drive receives a new absolute positioning command while the previous positioning command is
still in progress, it completes the previous command and then executes the new positioning command. On-
ly 1 positioning command can be buffered at a time.
Parameter 17-91 Relative Position Mode
Table 960: Parameter 17-91 Relative Position Mode
17-91 Relative Position Mode
Default value: [0] Target position
Parameter type: Option
Setup: All setups
Conversion index: -
Data type: Uint8
Change during operation: False
N O T I C E
This parameter is only available with software version 48.XX.
Select which reference to use for relative positioning commands.
AU275636650261en-000101 / 130R0334
534 | Danfoss A/S © 2022.12
Parameter Descriptions
VLT AutomationDrive FC 301/302
Programming Guide
Summary of Contents for VLT AutomationDrive FC 301
Page 2: ......